DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming Explanation of special flags (SM) and registers (SR) for ASDA CANopen communication instructions The following table shows special flags (SM) and registers (SR) related to ASDA CANopen communication. The following table shows how Delta servo parameters of axes correspond to special flags and registers in the CANopen communication. 3-550 Flag ID. 1 ID. 2 ID. 3 ID. 4 ID. 5 ID. 6 ID. 7 ID.

8 Enable specific function M1614 Initialization and communication complete flags for INITC and CASD instructions M1615 Communication error M1616 Pulse output complete M1624 M1625 M1626 M1627 M1628 M1629 M1630 M1631 Deceleration and then stop M1632 M1633 M1634 M1635 M1636 M1637 M1638 M1639 Servo-ON M1640 M1641 M1642 M1643 M1644 M1645 M1646 M1647 Go-back/go-forth enabled Only DDRVAC is supported. M1648 M1649 M1650 M1651 M1652 M1653 M1654 M1655 Go-back/go-forth direction indicator Only DDRVAC is supported.

M1656 M1657 M1658 M1659 M1660 M1661 M1662 M1663 Heartbeat error code (for firmware V3.60 and later) M1664 M1665 M1666 M1667 M1668 M1669 M1670 M1671 Heartbeat error handling (for firmware V3.60 and later) M1617 = OFF (default; when one goes down, all the drivers are OFF.) M1617 = ON (when one goes down, only the defective driver is OFF.) Number of the axis with a communication error D6000 Communication error code D6001 STEP that when error occurs D6002 Servo Parameter Name (Number) ID. 1 ID. 2 ID. 3 ID. 4 ID. 5 ID. 6 ID. 7 ID.

8 PR command (P5 07) _ D6008 D6009 D6010 D6011 D6012 D6013 D6014 D6015 Alarm code (P0 01) _ (hexadecimal) D6016 D6017 D6018 D6019 D6020 D6021 D6022 D6023 DO state (P0 46) _ D6024 D6025 D6026 D6027 D6028 D6029 D6030 D6031 Servo current position (P0 09) _ D6032 D6034 D6036 D6038 D6040 D6042 D6044 D6046