Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set If there is a communication error in the execution, shoot the trouble and then re-enable the instruction to write all data. Example 1. When M1 = OFF → ON, data are written in D device. 2. When M1 = OFF → ON, the instruction writes a 32-bit value for P1-44 of the servo whose station address is 2 and the written value 77777777 is stored in D52. The instruction writes a 32-bit value for P1-45 and the written value 88888888 is stored in D56. As the writing is complete, M201 turns ON. 3-563 Subindex Instruction name Data No.

Index address Written data source address DCOPWL (Writes 32-bit values) 1 D50 = 16#212C (E-gear ratio numerator) D51 = 0 D52, D53 = 77777777 2 D54 = 16#212D (E-gear ratio denominator) D55 = 0 D56, D57 = 88888888