DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 2-36 OFF STOP RUN Special ES2 SA2 Latch Content SS2 SX2 Attrib. Default D EX2 SE -ed ON RUN STOP setting if “0” is specified. D1250 COM1 (RS-232) communication error code (only applicable for MODRW/RS instruction) ○ ○ ○ ○ 0 - - R/W NO 0 D1252 Set value for COM3 (RS-485) data receiving time-out (Unit: 1ms, min.
50ms, value smaller than 50ms will be regarded as 50ms) (only applicable for MODRW/RS instruction) In RS instruction, no time-out setting if “0” is specified ○ ╳ ○ ╳ 50 - - R/W NO 50 D1253 COM3 (RS-485) communication error code (only applicable for MODRW/RS instruction) ○ ╳ ○ ╳ 0 - - R/W NO 0 D1255* COM3 (RS-485) PLC communication address ○ ╳ ○ ○ 50 - - R/W YES 1 D1256 ↓ D1295 For COM2 RS-485 MODRW instruction. D1256~D1295 store the sent data of MODRW instruction. When MODRW instruction sends out data, the data will be stored in D1256~D1295. Users can check the sent data in these registers. ○ ○ ○ ○ 0 - - R NO 0 D1296 ↓ D1311 For COM2 RS-485 MODRW instruction.
D1296~D1311 store the converted hex data from D1070 ~ D1085 (ASCII). PLC automatically converts the received ASCII data in D1070 ~ D1085 into hex data. ○ ○ ○ ○ 0 - - R NO 0 D1312* Specify the number of additional pulses for additional pulses output and Z-phase seeking function of ZRN instruction (Has to be used with M1308) ○ ╳ ○ ○ 0 0 - R/W NO 0 D1313* Second of RTC: 00 ~ 59 ○ ○ ○ ○ - - - R/W YES 0 D1314* Minute of RTC: 00 ~ 59 ○ ○ ○ ○ - - - R/W YES 0 D1315* Hour of RTC: 00 ~ 23 ○ ○ ○ ○ - - - R/W YES 0 D1316* Day of RTC: 01 ~ 31 ○ ○ ○ ○ - - - R/W YES 1 D1317* Month of RTC: 01 ~ 12 ○ ○ ○ ○ - - - R/W YES 1 D1318* Week of RTC: 1 ~ 7 ○ ○ ○ ○ - - - R/W YES 2 D1319* Year of RTC:
00 ~ 99 (A.D.) ○ ○ ○ ○ - - - R/W YES 8 D1320* ID of the 1st right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1321* ID of the 2nd right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1322* ID of the 3rd right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1323* ID of the 4th right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1324* ID of the 5th right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1325* ID of the 6th right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1326* ID of the 7th right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1327* ID of the 8th right side module ○ ╳ ╳ ╳ 0 - - R NO 0 D1336 PV of Y2 pulse output (Low word) ○ ○ ○ ○ - - - R/W YES 0 D1337 PV of Y2 pulse output (High word) ○ ○ ○ ○ - - - R/W YES 0 D1338 PV of Y3 pulse output (Low word) ○ ○ ○ ○ - - - R/W NO 0 D1339 PV of Y3 pulse output (High word) ○ ○ ○ ○ - - - R/W NO 0 D1340 Start/end frequency of the 1st group pulse output CH0 (Y0, Y1) ○ ○ ○ ○ 100 - - R/W NO 100 D1343 Ramp up/down time of the 1st group pulse output CH0 (Y0, Y1) ○ ○ ○ ○ 100 - - R/W NO 100 D1348* When M1534 = ON, D1348 stores the ramp-down time of CH0(Y0, Y1) pulse output.
○ ○ ○ ○ 100 - - R/W NO 100 D1349* When M1535 = ON, D1349 stores the ramp-down time of CH1(Y2, Y3) pulse output. ○ ○ ○ ○ 100 - - R/W NO 100 D1352 Start/end frequency of the 2nd group pulse output CH1 (Y2, Y3) ○ ○ ○ ○ 100 - - R/W NO 100 D1353 Ramp up/down time of the 2nd group pulse output CH1 (Y2, Y3) ○ ○ ○ ○ 100 - - R/W NO 100 D1354 PLC Link scan cycle (Unit: 1ms) Max: K32000 D1354 = K0 when PLC Link stops or when the first scan is completed ○ ○ ○ ○ 0 0 0 R NO 0