DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 14. The already used communication ports are as below. 15. Descriptions for relevant flags during communication: TCP MODE: M1196=ON: Communication port is connected Master/Slave mode; communication is working fine. M1197 = ON, this indicates the communication is active. Make sure the TCP connection is ready or is waiting to be connected and checking its relative communication settings are set, the data length is less than 200 characters and if the slave is responding. After data is sent or received, M1197 stays ON and a completion flag will be set to ON.
(You can reset this flag to OFF.) If the ETHRS instruction is executed again, the completion flag will be reset to OFF.
3-572 Error code Description H6201 Illegal TCP Socket communication mode setting H6202 Illegal TCP Socket mode setting H6203 TCP Socket illegal address for sending data H6204 TCP Socket the length of sent data exceeds the range H6205 TCP Socket the device where data are sent exceeds the range H6206 TCP Socket illegal address for receiving data H6207 TCP Socket the length of received data exceeds the range H6208 TCP Socket the device for receiving data exceeds the range H6212 TCP Socket communication timeout H6213 TCP Socket the size of data actually received is larger than the set data.
H6214 TCP Socket connection is rejected by the remote equipment H6215 TCP Socket has not been connected H6217 TCP Socket connection has been triggered. UDP/TCP Communication Description Port TCP 502 Modbus TCP communication TCP 44818 EtherNet/IP explicit message UDP 67 DHCP communication UDP 68 UDP 2222 EtherNet/IP implicit message UDP 44818 EtherNet/IP explicit message UDP 20006 For internal parameter download UDP 20008