3. Instruction Set Selecting 2.0B mode: (Here is the introduction of receiving data from 1 slaves. For other data, increase the number of D 1 ) NOTE: if the Msg. ID of the next slave is 0, it indicates there is no data to be received. 11. When the instruction is set to the slave mode and set to receive after sending (M1621=ON, requirements on the receivers, use the broadcast mode instead. When the receiver’s ID is met M1622=OFF), the Msg. ID of D 1 is the receiving condition on ID. Therefore, if there is no with the set ID, the instruction sends data and after sending is complete, a completion flag will be set in D 2 .
If the sending data length is 0, the instruction does not send data and set a completion flag in D 2 . 12. When the instruction is set to the slave mode and set to receive only (M1621=ON, M1622=ON), the receiving mode will be broadcast. This mode can be ended when timeout (D1177) occurs (M1623=ON) or when the value in D1175 is exceeding 100 packet limit (M1623=ON). If you still need to receive data when this mode is ended, you can stop executing this instruction for a scan cycle and start this mode again. Every time you reset this mode, the 13. D 2 is communication completion flag and only M device can be used. When the completion receiving log in D1175 will be cleared.
flag is ON, it indicates receiving is complete. The completion flag can be set to ON when the instruction is scanned and the communication is complete. From the status of the completion flag, you can tell if the communication is complete. The status of this flag will be clear each time this instruction is executed. You do not need to clear its status. 14. When the instruction is set to the master mode (M1621=OFF), it is recommended to use it to work with D1177 to set the communication timeout. If the communication packet has not been received fully within the specified period of time, the M1623 will be ON.
The setting range for 3-583 Response Data from Data from Data from sequence the first slave the second slave the third slave D100 D101 D102 ~ D109 (Lower 8 bits) D110 D111~D119 D120~129 D No. 1 Msg. ID Data Length Data1 ~ Data8 Msg. ID Length, Data ID, Length, Data Description Response Data from Data from the second sequence the first slave slave D No. 1 D100 D101 D102 D104 ~ D111 (Lower 8 bits) D112~D122 Descriptio n Msg. ID (Lo-word) Msg. ID (Hi-word) Data Length Data1 ~ Data8 ID, Length, Data