Delta DVP-ES2 — 7.4.4 Example on Sending SDO through the Ladder Diagram

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming meantime, you should check if the data in Emergency message are correct.  Node ID: The node address of the target equipment on CANopen network.  Total number of data: The total number of Emergency messages CANopen master receives from the slave.  Number of data stored: The latest number of Emergency messages CANopen master receives from the slave. (5 messages at most)  The data in D6004-D6007 are the content of Emergency 1 and every Emergency message consists of 8 bytes of data. The data format of Emergency message on CAN bus is shown below.

Datum 0~ datum 7 in Emergency response message correspond to byte 0~ byte 7 respectively Example 1: Read the Emergency message of slave of No.2 and the Emergency messages the slave sends out successively are shown below.  Request data:  Emergency response data 7.4.4 Example on Sending SDO through the Ladder Diagram Read the value of P0-09 of servo in cycle through SDO.  Hardware Connection:  Control Requirement:

7-20 COB-ID Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 80(hex) +Node-ID Emergency error code Error storage register Vendor custom error code COB-ID Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 82(hex) 43 54 20 14 0 0 0 0 COB-ID Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 82(hex) 42 54 20 15 0 0 0 0 Request message PLC device High byte Low byte D6250 Message header ReqID=01 Reserved Type =04 Command =01 D6251 Size =0 D6252 Node ID =02 PLC device Response message High byte Low byte D6000 Message header ResID=01 Status code =01 D6001 Reserved =0 Size =2A (Hex) D6002 Type =04 Node ID =02 D6003 Message data Total number of data =1 Number of data stored =1 D6004 Datum 1=54 Datum 0=42 D6005 Datum 3=15 Datum 2=20 D6006 Datum 5=0 Datum 4=0 D6007 Datum 7=0 Datum 6=0 D6004 Datum 1=54 Datum 0=43 D6005 Datum 3=14 Datum 2=20 D6006 Datum 5=0 Datum 4=0 D6007 Datum 7=0 Datum 6=0