7 CANopen Function and Operation PDO transmission type can be synchronous transmission and asynchronous transmission. In synchronous transmission, master will send out the SYNC message in the fixed cycle. The length of the cycle is set in master properties dialog box with the default value: 50ms. In asynchronous transmission, the message is sent out once the PDO mapping parameter is changed. PDO Transmission types in details are introduced in the following table. Note : 1> Synchronous transmission type can fulfill multi-axis motion at the same time.
2> If user is going to monitor the real-time changing parameter such as the actual rotation speed of the motor, we suggest TxPDO should be set as the synchronous transmission type in case the frequent changing of slave data causes to block the CANopen network. 3> After the above setting is finished, double click the master, select ASDA-A2 Drive, and click “ > ” to move A2 to the right list and download the configured data. 7-31 Transmission Type Description Remark 0 RxPDO Once any change for the mapped data happens, RxPDO data are sent out immediately. The data that slave receives are valid only when receiving the next SYNCH message. If no change for RxPDO data, they are not sent out.
SYNCH SYNCH non-cycle TxPDO Once any change for the mapped data happens and slave receives the SYNC message, the data are sent out immediately. The TxPDO data are valid immediately after master receives them. If no change for TxPDO data, the data are not sent out. N (N:1~240) RxPDO After N messages are sent out and no matter whether the mapped data are changed, the data that slave receives will be valid only when receiving the next SYNCH message. SYNCH cycle TxPDO After N messages are sent out and no matter whether the mapped data are changed, the data that master receives will be valid at once.
254 RxPDO The mapped data are sent out immediately once changed and they are valid once they are received by slave. RxPDO data will not be sent out if no change for the data. ASYNCH TxPDO Slave sends out the data once every one Event timer time and after that, the TxPDO data are not allowed to be sent out within an inhibit timer time. When Event timer and Inhibit timer are both equal to 0, TxPDO data are sent to master immediately once changed and the data that master receives will be valid at once. 255 Same as Type254