Delta DVP-ES2 — B.5.2 EtherNet/IP Objects Supported by DVP-SE / ES2-E Series PLCs

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming ES2-E & DVP26SE: (0x350) (5) Y output DVP12SE: (0x65) ES2-E & DVP26SE: (0x351) (6) T timer DVP12SE: (0x66) ES2-E & DVP26SE: (0x355) B-16 Instance Attribute Name Access Data Type 1 0 X0 Get BOOL 1 1 X1 Get BOOL …… 1 255 X377 Get BOOL Instance Attribute Name Access Data Type 1 0x64 Y0 Set BYTE ( 0x00 or 0x01 ) 2 0x64 Y1 Set BYTE ( 0x00 or 0x01 ) …… 256 0x64 Y377 Set BYTE ( 0x00 or 0x01 ) Instance Attribute Name Access Data Type 1 0 Y0 Set BOOL 1 1 Y1 Set BOOL …… 1 255 Y377 Set BOOL Instance Attribute Name Access Data Type 1 0x64 T0 Set INT 2 0x64 T1 Set INT ……

256 0x64 T255 Set INT Instance Attribute Name Access Data Type 1 0x65 T0 Set BYTE ( 0x00 or 0x01 ) 2 0x65 T1 Set BYTE ( 0x00 or 0x01 ) …… 256 0x65 T255 Set BYTE ( 0x00 or 0x01 ) Instance Attribute Name Access Data Type 1 0 T0 Bit Set BOOL 1 1 T1 Bit Set BOOL …… 1 255 T255 Bit Set BOOL Instance Attribute Name Access Data Type 2 0 T0 Register Set INT 2 1 T1 Register Set INT …… 2 255 T255 Register Set INT