Delta DVP-ES2 — B.6 RTU Mapping

Appedndix B Setting and Using an Ethernet PLC/Module (11) Ethernet Link Object (0xF6) Instance: 0x01 B.6 RTU Mapping means of RTU mapping. After the users finish setting mapping information, they can operate Users can connect the Delta network product DVPEN01-SL/DVP-SE/ES2-E to RTU-EN01 by RTU-EN01 by means of corresponding bits (M devices) and registers (D devices) in DVPEN01-SL/DVP-SE/ES2-E instead of communication programs. B-19 Domain Name STRING 0x06 Host Name Get STRING DVP12SE or ES2-E 0x0D Encapsulation Inactivity Timeout Set UINT Keep Alive Timeout 120 s Attribute Name Access Data Type Value 0x01 Interface Speed Get UDINT 10 or 100 Mbps 0x02 Interface Flag Get UDINT Bit 0:

Link Status Bit 1: Half/Full Duplex 0x03 MAC Address Get USINT[6] 0x0A Interface Label Get SHORT _ STRING Define Ethernet port name 0x0B Interface Capability Get STRUCT of: 01 31 Capability Bits DWORD 00 00 00 07 Speed/Duplex Array Count USINT 04 Interface Speed 1 UINT 00 0A Interface Duplex Mode 1 USINT 00 Interface Speed 2 UINT 00 0A Interface Duplex Mode 2 USINT 01 Interface Speed 3 UINT 00 64 Interface Duplex Mode 3 USINT 00 Interface Speed 4 UINT 00 64 Interface Duplex Mode 4 USINT 01