Delta Electronics DVP-ES3 — 5.3.3 DVP06XA-E2 Control Registers

DVP-ES3 Series Operation Manual 5.3.3 DVP06XA-E2 Control Registers _5 5-28 CR# Attrib. Register name Explanation 0 O R Model name Set up by the system: DVP06XA-E2 model code = H’00C4 1 O R Firmware version Display the current firmware version in hex. 2 O R/W CH1 Input mode setting Input mode: Default = H’0000. Take CH1 for example:

Mode 0 (H’0000):Voltage input (±10V) Mode 1 (H’0001):Voltage input (±5V) Mode 2 (H’0002):Voltage input (0 ~+10V) Mode 3 (H’0003):Voltage input (0 ~+5V) Mode 4 (H’0004):Current input (±20mA) Mode 5 (H’0005):Current input (0 ~+20mA) Mode 6 (H’0006):Current input (4 ~+20mA) Mode -1 (H’FFFF):Channel 1 unavailable 3 O R/W CH2 Input mode setting 4 O R/W CH3 Input mode setting 5 O R/W CH4 Input mode setting 6 O R/W CH5 output mode setting Output mode: Default = H’0000. Take CH5 for example:

Mode 0 (H’0000):Voltage output (±10V) Mode 1 (H’0001):Current output (0~+20mA) Mode 2 (H’0002):Current output (4~+20mA) Mode -1 (H’FFFF):Channel 5 unavailable 7 O R/W CH6 output mode setting 8 O R/W CH1 average times Average times setting of CH1 ~ CH4: Range = K1 ~ K100 Default = K10 9 O R/W CH2 average times 10 O R/W CH3 average times 11 O R/W CH4 average times 12 X R CH1 average input value Average value of input signals at CH1 ~ CH4 13 X R CH2 average input value 14 X R CH3 average input value 15 X R CH4 average input value 16 X R/W CH5 output signal value Voltage output range: K-32,000~K32,000. Current output range: K0~K32,000. Default: K0.

17 X R/W CH6 output signal value 20 X R CH1 present input value Present value of input signals at CH1 ~ CH4 21 X R CH2 present input value 22 X R CH3 present input value 23 X R CH4 present input value 28 O R/W Adjusted Offset value of CH1 Set the adjusted Offset value of CH1 ~ CH6 Default = K0. Definition of Offset in DVP06XA -E2: The corresponding voltage (current) input value when the digital output value = 0 29 O R/W Adjusted Offset value of CH2 30 O R/W Adjusted Offset value of CH3 31 O R/W Adjusted Offset value of CH4 32 O R/W Adjusted Offset value of CH5 33 O R/W Adjusted Offset value of CH6 34 O R/W Adjusted Gain value of CH1 Set the adjusted Gain value in CH1 ~ CH6 Default = K16,000.

Definition of Gain in DVP06XA-E2: The corresponding voltage (current) input value when the digital output value = 16,000. 35 O R/W Adjusted Gain value of CH2 36 O R/W Adjusted Gain value of CH3 37 O R/W Adjusted Gain value of CH4 38 O R/W Adjusted Gain value of CH5 39 O R/W Adjusted Gain value of CH6