Chapter 5 CPU and Module Devices 5_ ※ CR#0 for module reset You can use CR#0 to reset all the settings by simply writing H’4352 in CR#0 and wait for one second before turning the power OFF and then ON again, all the modules connected will be initialized. It is suggested to connect to only one module for module reset. And this is only available for firmware V1.14 or later. ※ CR#43: Error status value. See the table below: 5-29 CR# Attrib. Register name Explanation Adjusted Offset Value, Adjusted Gain Value: Note 1: When using Mode 6 for input or Mode 2 for output, the channel do NOT provide setups for adjusted Offset and Gain value. Note 2:
When mode changes, the adjusted Offset and Gain value returns to defaults. 40 O R/W Set value changing prohibited Prohibit set value changing in CH1 ~ CH4 Default= H’0000. 41 X R/W Save all the set values Save all the set values, Default =H’0000 43 X R Error status Register for storing all error status. Refer to table of error status for more information. 100 O R/W Enable/Disable limit detection Upper and lower bound detection, b0~b5 corresponds to CH1~CH6 (0: Disable/ 1: Enable). Default= H’0000. 101 X R/W Upper and lower bound status Display the upper and lower bound status. (0: Not exceed /1:
Exceeds upper or lower bound value), b0~b5 corresponds to Ch1~Ch6 for lower bound detection result; b8~b13 corresponds to CH1~CH6 for upper bound detection result. 102 O R/W Set value of CH1 upper bound Set value of CH1~CH6 upper bound. Default = K32000. 103 O R/W Set value of CH2 upper bound 104 O R/W Set value of CH3 upper bound 105 O R/W Set value of CH4 upper bound 106 O R/W Set value of CH5 upper bound 107 O R/W Set value of CH6 upper bound 108 O R/W Set value of CH1 lower bound Set value of CH1~CH6 lower bound. Default = K-32000.
109 O R/W Set value of CH2 lower bound 110 O R/W Set value of CH3 lower bound 111 O R/W Set value of CH4 lower bound 112 O R/W Set value of CH5 lower bound 113 O R/W Set value of CH6 lower bound 114 O R/W Output update time of CH5 Set output update time of CH5 ~ CH6 115 O R/W Output update time of CH6 118 O R/W LV output mode setting of Ch5 ~ Ch6 Set the output mode of CH5~CH6 when the power is at LV (low voltage) condition. Default=0 Symbols: O: When CR#41 is set to H’5678, the set value of CR will be saved. X: Set value will not be saved. R: You can use FROM instruction to read data. W: You can use TO instruction to write data.
Description bit0 K1 (H’1) Power supply error bit6 K64 (H’40) CH4 Conversion error bit1 K2 (H’2) Hardware error bit9 K512 (H’0200) Mode setting error bit2 K4 (H’4) Upper/lower bound error bit10 K1024 (H’0400) Sampling range error bit3 K8 (H’8) CH1 Conversion error bit11 K2048 (H’0800) Upper / lower bound setting error bit4 K16 (H’10) CH2 Conversion error bit12 K4096 (H’1000) Set value changing prohibited