Delta Electronics DVP-ES3 — 8.2.2.4 Options - Ethernet Port Advanced Setting

Chapter 8 Hardware Configuration  Select RTU1 Enable to enable this RTU function. You can set each RTU individually.  Set a station address and an IP address.  Set the RX mapping address and RX mapping length to make the digital input points for the DI module connected to RTU and mapped to X/M devices, as well as the length for the DVP-ES3 Series module. Set the RY mapping address and length to set the digital output points for the DO module mapped to Y/M devices, as well as the length for the DVP-ES3 Series module.

 Set the RCR Read mapping address and RCR Read mapping length to make the analog input points for the AI module connected to RTU and mapped to D/SR devices, as well as the length for the DVP-ES3 Series module. Use the RCR Write mapping address and length to set the analog output points for the AO module mapped to D/SR devices, as well as the length for the DVP-ES3 Series module. 8_ 8-23