DVP-ES3 Series Operation Manual 10.6 Application Example The DVP-ES3 Series PLC can control Delta A2 servo rotation, and monitor the actual rotation speed of the motor in real time. It does this by mapping the relevant servo drive parameters to the corresponding PDO, and reads or writes the relevant servo drive parameters through the CAN bus. 1. Connectting the Hardware Note: Use a standard communication cable such as UC-DN01Z-01A / UC-DN01Z-02A / UC-CMC010-01A and connect the terminal resistors (Delta standard terminal resistor TAP-TR01) to both ends of the network when you construct the network.
M of ASD-A2-xxxx-M refers to the model code and currently only the M-model servo supports CANopen communication. 2. Setting Servo Parameters: Set servo parameters as shown in the following table. _10 10-30 Parameter Setting Explanation 3-00 03 Node ID of the A2 servo is 2 3-01 400 CAN communication rate is 1Mbps. 1-01 04 Speed mode 0-17 07 Drive displays the motor rotation speed (r/min) 2-10 101 Set DI1 as the signal for Servo On 2-12 114 Set DI3 as the signal SPD0 for speed selection _ 2-13 115 Set DI4 as the signal SPD1 for speed selection _