Delta DVP-ES3 — 4.6.1.2 Relay Types

DVP-ES3 Series Operation Manual 4.6 Wiring CPU Modules 4.6.1 Wiring Digital Input Terminals 4.6.1.1 Direct Current Power Supply (24 VDC) When the digital input signal is DC input, there are two DC input types, Sinking and Sourcing. See the definition below. 4.6.1.2 Relay Types  Sinking  Sourcing 4-14  Sinking Sink = The current flows into the common terminal S/S. S/S X0  Sourcing Source = The current flows from the common terminal S/S. X0 S/S 4 _ Inter nal circui t I/O X0 Internal ci rcuit S/S + 24VDC Internal ci rcuit Internal ci rcuit I/O X0 Internal circuit S/S + 24VD C