DVP-ES3 Series Programming Manual _6 Symbol S 1 : Target number of output pulses S 2 : Target output frequency S 3 : Input point number for receiving the external interrupt signal S 4 : The number of output pulses at the end for the fore mask section S 5 : The number of output pulses at the beginning for the rear mask section S 6 : The number of output pulses in the ramp-down process after the interrupt signal is received D 1 : Pulse output device D 2 : Direction pulse output device Explanation 1. This instruction performs mark alignment positioning.
When the value of S 1 is 0, it indicates the output is a maximum 32-bit value (with a sign) and the output does not perform the ramp-down stop until receiving the mark signal. 6-810 API Instruction Operand Description 2709 D DRVM S1,S2,S3,S4,S5,S6,D1,D2 Mark alignment positioning Device X Y M S T C HC D FR SM SR E K 16# “$” F S1 S2 S3 S4 S5 S6 D1 D2 BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S1 S2 S3 S4 S5 S6 D1 D2 Pulse Instruction 16-bit instruction 32-bit instruction - - ES3