Chapter 6 Applied Instructions If the value of S 1 is not 0 and the external interrupt does not occur, the target number output pulses are output. The range of S 1 is between -2,147,483,648 to +2,147,483,647, and the +/- sign means the positive or negative direction. 2. When the value of S 2 is less than or equal to 0, the output is not enabled. If the output frequency is greater than the maximum frequency, the PLC processes it as the maximum output frequency. 3. S 3 can specify the X0~X7 and X10~X17 device as the input point. The input source signal is affected by the scan cycle if the selected input point is not in M0–X15 in the PLC. 4.
You must use the instruction by combining the input point number and the external interrupt program to achieve the the external interrupt program in ISPSoft. real-time ramp-down output. For the rising-edge or falling-edge trigger for the external interrupt, select the triggers in A. Using the external interrupt (e.g. I0xx, I1xx): when the external interrupt occurs, the ramp-down stop is performed after the mark signal is received. No operation is performed if the external interrupt is not enabled. B. Without using the external interrupt (I0xx, I1xx):
When the instruction is executed, the ramp-down stop is performed after the mark signal is received if the rising edge occurs at X point or M device. It is affected by the scan time. 5. The number of output pulses in the fore mask section is between 1– S 4 . When the setting value for S 4 is 0, it means the fore- mask section function is disabled. When the number of pulses to be masked exceeds the value of S 1 , the instruction takes the target number of output pulses S 1 as the number to be masked. If the external input trigger occurs within the number of output pulses to be masked, the external input interrupt is automatically invalid. 6_ 6.
The number of output pulses in the rear mask section is between S 5 and S 1 . When S 5 =0 or S 5 >= S 1, the rear mask section function is disabled. When the external input trigger occurs in the masked sections, the external input interrupt is automatically invalid. When S 4 > S 5, it indicates the external input interrupt is invalid in the output process. 7. If the fore and rear mask sections are both set and S 4 S 5, the valid input interrupt occurs in the section between S 4 +1 and S 5 -1. 8. 6-811 S6:
the number of output pulses in the ramp-down Description If S6 is set to 0 after the mark signal is received the ramp-down stop is performed based on the ramp-down time If S6 =-1 or the output immediately stops If the setting value of S6 is not enough to achieve the ramp-down stop within the ramp-down time, The instruction limits the target frequency and performs the ramp-down stop in accordance with the set