DVP-ES3 Series Programming Manual 4. The PLC assigns the value of S 3 to the X or Y axis depending on which outputs the largest number of pulses. If the numbers of pulses output for the two axes are excessively different, so that no proper output frequency can be calculated through the numbers of their output pulses, the PLC automatically decreases the maximum point to point frequency and without any error message appearing. 5. The instruction uses the parameters such as the start and end frequencies and ramp-up and ramp-down times for the axes the instruction executes. Instead of the originally configured parameters for the axes, the X axis parameters are taken as the reference source.
For example, when the X axis selects axis 1 and the Y axis selects axis 3 for the output, axis 1 parameters become the parameter sources for the start frequency and ramp up and ramp-down time. 6. The following table shows the flags for the axes and the corresponding SM/SR. _6 7. There is no limit to how many times you can use the instruction in a program. But during the execution of the instruction, it cannot execute the output (if the Y axis output is being used) until the Y axis completes its output and is released. 8. When the 2-axis synchronized pulse output completes, the corresponding Completion flags for the two axes is set.
Since the same timing for the completion of the 2-axis synchronized pulse output cannot be ensured every time, the program should check the Completion flags of both axes before executing the next user program. 6-820 Axis number Axis 1 Axis 2 Axis 3 Axis 4 Output point for D1 Y0 Y2 Y4 Y6 Direction output point for D2 Y1 Y3 Y5 Y7 SR number SR462 SR482 SR502 SR522 Axis number Axis 1 Axis 2 Axis 3 Axis 4 Busy flag SM460 SM480 SM500 SM520 Completion flag SM461 SM481 SM501 SM521 Present output position SR460 SR461 SR480 SR481 SR500 SR501 SR520 SR521 Start/end frequency SR463 SR483 SR503 SR523 Ramp-up time SR464 SR484 SR504 SR524 Ramp-down time SR465 SR485 SR505 SR525