DVP-ES3 Series Programming Manual Symbol S 1 : A number listed in the position planning table S 2 : Target position S 3 : Target speed _6 Explanation 1. This instruction sets the single-axis output parameters in the position planning table. S 1 is the number listed in the motion, or under Single-axis multi-segment motion, the instruction is not executed, SM0 is ON and the error code is position planning table. If the number does not exist in the table, or the number is not under Single-axis point-to-point SR0=16#2027. 2. S 2 is the target position (must be a 32-bit integer).
If you use the mechanical unit conversion when editing the position planning table in ISPSoft, use the conversion instruction for modification first. 3. S 3 is the target speed. The range is between 1–200,000Hz. 4. When the instruction is executed to modify the parameters for the single axis which is outputting pulses, the modified parameters are kept in the table and are not effective until the next output starts.
6-854 API Instruction Operand Description 2719 D TPWS P S1,S2,S3 Setting single-axis output parameters in the position planning table Device X Y M S T C HC D FR SM SR E K 16# “$” F S1 S2 S3 BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S1 S2 S3 Pulse Instruction 16-bit instruction 32-bit instruction ES3 - ES3