Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

Chapter 6 Applied Instructions Example 3: Use abort symbol and completion flag 1. Set up the positioning planning table as shown below. 2. Abort symbol: When No. 3 stops the outputting abruptly, M100 is ON and the system starts to output No. 4 immediately. The abort symbol is applicable for the following conditionss: external interrupts, high-speed comparision interrupts and M devices (M0~8191). 3. Completion flag: When No. 4 completes the outputting, M777 is ON. When the execution of this positioning planning table is complete, the system calls for an interrupt or starts a M device. You can use the interupt numbers I510~519 and M device (M0~M8191) in the positioning planning table. Note:

If you use interrupts instead of M devices, PLC scan cycle is not affected. 6_ 6-853