Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

DVP-ES3 Series Programming Manual Symbol _6 S 1 : A number listed in the position planning table S 2 : X axis target position S 3 : Y axis target position S 4 : The shift of the center S 5 : Target speed Explanation 1. This instruction sets the 2-axis arc interpolation parameters in the position planning table. S 1 is the number listed in the position planning table. If the number does not exist in the table, or the output of the number does not belong to the 2-axis arc interpolation, the instruction is not executed, SM0 is ON and the error code is SR0=16#2027.

6-858 API Instruction Operand Description 2721 D TPWC P S1,S2,S3,S4,S5 Setting arc interpolation parameters in the position planning table Device X Y M S T C HC D FR SM SR E K 16# “$” F S1     S2     S3     S4     S5     BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S1   S2   S3   S4   S5   Pulse Instruction 16-bit instruction 32-bit instruction ES3 - ES3