Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

DVP-ES3 Series Programming Manual The steps for performing the functions are as below Function code 0:  The DZRN2 function is executed and the search for the zero point is in the negative direction with the target frequency ( TFreq ).  After the DOG signal is received, the output frequency decreases to the JOG frequency ( JFreq ). The output continues in the negative direction and does not stop until the zero point signal changes from ON to OFF.  The output stops when the signal changes from ON to OFF and the axis moves away from the DOG signal. Negative direction Completion flag ON DOG signal ON Frequency Target frequency JOG frequency Time Function code 1:

1 2 3 _6  The DZRN2 function is executed and the search for the zero point is in the negative direction with the target frequency ( TFreq ).  After the DOG signal is received, the output is in the positive direction with the JOG frequency ( JFreq ) after the output frequency decreases, and the motion direction reverses. The output does not stop until the zero point signal changes from ON to OFF.  The axis moves away from the DOG signal and PLC stops when the signal changes from ON to OFF. Negative direction Positive direction Completion DOG signal Target frequency JOG frequency Time 1 2 3 4 6-870 g l uency ON ON