Delta DVP-ES3 — 6.27.2 Explanation of CANopen Communication Instructions

DVP-ES3 Series Programming Manual Symbol S 1 : Station address of the servo S 2 : Servo ON and Servo OFF Explanation _6 1. This instruction changes the state of the servo at the address in S 1 . The INITC instruction must be complete before this instruction is executed. 2. The range of S 1 is 1–8 (for servo) and 21-28 (for inverter). There will be no execution when the input value is out of the range. 3. The range of S 1 is 1–8 (for servo) and S 2 is a non-zero value, the servo is enabled (Servo-ON). If S 2 is 0, the servo is disabled (Servo-OFF). 4. The range of S 1 is 21–28 (for inverter). When S 2 is 1, it indicates it is in inverter speed mode.

When S 2 is 2, it indicates it is in inverter torque mode. When S 2 is 0, it indicates it stops operating. Since control modes (speed mode and torque mode) for inverters can be switched directly, the operation can keep going. Before switching control modes, make sure all the inverter parameters are set. 6-880 API Instruction Operand Description 2801 ASDON S1,S2 Servo-ON and Servo-OFF Device X Y M S T C HC D FR SM SR E K 16# “$” F S1           S2   BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S1    S2    Pulse instruction 16-bit instruction 32-bit instruction - ES3 -