Delta DVP-ES3 — 6.27.2 Explanation of CANopen Communication Instructions

DVP-ES3 Series Programming Manual Symbol S 1 : Station address of servo S 2 : The 1 st – segment speed S 3 : The 2 nd – segment speed _6 Explanation 1. This instruction executes the servo homing control for the servo at the address specified in S 1 . The INITC and ASDON (Servo-ON) instructions must be complete before this instruction is executed. It is recommended to use the instruction ZRNM (API 2810) to have every servo axis go back to the zero point. 2. The range of S 1 is 1–8 (for servo. There will be no execution when the input value is out of the range. 3. The range of S 2 is 1–20000. Unit: 0.1 rpm 4. The range of S 3 is 1–5000. Unit: 0.1 rpm 5.

When the servo returns to the home position, the corresponding finish flags of the axes are ON. Refer to the DRVIC instruction (API 2803) for explanations of special flags (SM) and registers (SR). 6. SM1682 is set to ON when an error occurs during communication. In addition, SR658 retains the number of the axis in which the error occurs and SR659 retains the error code. Example 1. When M0 changes from OFF to ON, the INITC instruction starts to initialize servo 1, until SM1681 is ON.

6-898 API Instruction Operand Description 2806 ZRNC S1, S2, S3 Servo homing Device X Y M S T C HC D FR SM SR E K 16# “$” F S1    S2     S3     BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S1    S2    S3    Pulse instruction 16-bit instruction 32-bit instruction - ES3 -