Delta DVP-ES3 — 6.27.2 Explanation of CANopen Communication Instructions

Chapter 6 Applied Instructions 2. When M1 changes from OFF to ON, the acceleration time (10000) and deceleration time (20000) of servo 1 are set by using the CASD instruction (API 2802). When SM1651 is ON, it indicates Servo-ON. 3. When M2 changes from OFF to ON, 2-byte data is written to P5-04 in servo 1. When D100 = 5 and the data is written, M100 is ON. 4-byte data is written to P6-00 in servo 1. When D102 = 0 and the data is written, M101 is ON. 4-byte data is written to P6-01 in servo 1. When D104 = 0 and the data is written, M102 is ON. P5-04 sets the homing mode. P6-00 and P6-01 are the homing definitions. 4. When M3 changes from OFF to ON, the homing function is enabled for servo 1.

6_ 6-899