Delta DVP-ES3 — 6.27.2 Explanation of CANopen Communication Instructions

DVP-ES3 Series Programming Manual Example 1. When M1 = OFF → ON, data are written in D device. 2. When M1 = OFF → ON, the instruction writes a 32-bit value for P1-44 of the servo whose station address is 2 and the written value 77777777 is stored in D52. The instruction writes a 32-bit value for P1-45 and the written value 88888888 is stored in D56. As the writing is complete, M201 turns on. _6 6-908 Subindex Instruction name Data No. Index address Written data source address DCOPWL (Writes 32-bit values) 1 D50 = 16#212C (E-gear ratio numerator) D51 = 0 D52, D53 = 77777777 2 D54 = 16#212D (E-gear ratio denominator) D55 = 0 D56, D57 = 88888888