Delta DVP-ES3 — 6.19.2 Explanation of Communication Instructions

Chapter 6 Applied Instructions  The Ok flag is set to On after the PLC receives the communication data sent back from DMV. At the moment, the already received data can be processed.  The Start1 and Ok flags can be cleared to Off by manual.  If the detection need be retriggered to execute, directly set Start1 to On to start the next-round DMV detection. (Return to step 2 to continue.) Example 2 Mode = 1 Set1 and set2 are used to trigger the DMV detection separately. But the communication data reading command can not be sent until both Readys change to On. (The example is applicable to the two-camera DMV1000 detection.) See the sequence control diagram below.

En Start1 Shoot1 6_ Ready Start2 Shoot2 Com. port send receive Ok           The DMVSH instruction is enabled.  Set Start1 to On to notify the instruction to send the output signal Shoot1 (which is on for about 10ms) and notify DMV to enable the detection function of the first camera.  After DMV receives the trigger message, Ready is set from On to Off. 6-607