Delta DVP-ES3 — 6.19.3 Descriptions of the Communication-related Flags and Registers

Chapter 6 Applied Instructions 6.19.3 Descriptions of the Communication-related Flags and Registers Communication-related flags (SM) 6_ 6-609 Flag Description Action COM1 COM2 SM96 SM97 Data sending request flag If you want to use the instruction to send and receive data, you must use the pulse instruction to set the flag to ON. When the instruction is executed, the PLC sends and receives the data. After sending the data, the system automatically resets the flag to OFF. You set the flag to ON, and the system automatically resets it to OFF. SM98 SM99 When the flag is ON, the PLC is waiting to receive the data. The system automatically sets the flag to ON and resets it to OFF.

SM100 SM101 Reception complete flag After receiving the data, the system automatically sets the flag to ON. When the flag is ON, the data received can be processed. After processing the data received, you must to reset flags to OFF. The system automatically sets the flag to ON, and you reset it to OFF. SM102 SM103 Data receiving error flag An error occurs during receiving data using the data receiving instruction. The system automatically sets the flag to ON, and you reset it to OFF. SM104 SM105 Communication timeout error flag If you set the communication timeout (in SR) and no data is received after the timeout period, the flag is ON.

After the problem is solved, you must reset the flag to OFF. The system automatically sets the flag to ON, and you reset it to OFF. SM106 SM107 The choice between the 8-bit processing mode and the 16-bit processing mode ON: 8-bit processing mode OFF: 16-bit processing mode You set the flag to ON and reset it to OFF. SM210 SM212 Communication mode ON: RTU mode OFF: ASCII mode You can set this value in HWCONFIG in ISPSoft. Not available for Card1 and Card 2. You set the flag to ON and reset it to OFF.