DVP-ES3 Series Programming Manual 2. If the product serial no. is 32ES311TW19450012, the reading code of the instruction is 0 and the read data are stored in the devices starting from D0, the product serial no. is stored in the order as below. 3. If Mac ID is 16#123456789ABC, the reading code of the instruction is 1 and the read data are stored in the devices starting from D10, the Mac ID data are stored in the order as below. 4. If the already-power-on time is 70000 minutes (16#00011170), the reading code of the instruction is 2 and the read data are stored in the devices starting from D20, the already-power-on time data are stored in the order as below. 5.
Only the first-time execution of the INFO instruction is effective when the conditional contact is met. Therefore, it is recommended to use the pulse instruction INFOP. If the INFO instruction is used with the normally-open contact together, the instruction will be automatically executed only once. _6 Additional remark: If D is declared in a variable and the code is 0, 1 and 2, they can be declared respectively in ARRAY [9], [3], [2] of WORD. 6-624 D0 D1 D2 D3 D4 D5 D6 D7 D8 16#3233 16#5345 16#3133 16#5431 16#3157 16#3439 16#3035 16#3130 16#0032 ‘32’ ‘ES‘ ‘31’ ‘1T’ ‘W1’ ‘94’ ‘50’ ‘01’ ‘2’ D10 D11 D12 16#1234 16#5678 16#9ABC D20 D21 16#1170 16#0001