Delta DVP-ES3 — 6.22.2 Explanation of Ethernet Instructions

DVP-ES3 Series Programming Manual You can set up the email server related settings in ISPSoft > HWCONFIG > Setting > Options > Email. And from here you can also check the parameters which are set through instrucitons. But only the settings that are set in ISPSoft are retainable after power-off. 6-724 Operand Name Explanation Data type Remark User User name User +0: data length, unit: bytes (range: 0~31, 0: no modification.) User +1~ User +16: data content (Data are placed from the lower 8 bits.) For example: User D0 = 16#0004, D1 = 16#7355, D2 = 16#7265 WORD[N] Refer to User +0 for address occupation. 17 consecutive words at most can be occupied.

Up to 31 words can be used in one string String Passw Password Passw +0: data length, unit: bytes (range: 0~20, 0: no modification.) Passw +1~ Passw +10: data content (Data are placed from the lower 8 bits.) For example: Passw D0 = 16#0005,D1 = 16#5061, D2 = 16#7373,D3 = 16#0077 WORD[N] Refer to Passw +0 for address occupation. 11 consecutive words at most can be occupied. Up to 20 words can be used in one string String 6 _