Delta DVP-ES3 — 6.23.2 Explanation of Memory Card / File Register Instructions

Chapter 6 Applied Instructions  S 3 : The length of the data that the instruction reads from the file The devices in which the instruction stores the data cannot exceed the device range. If the value in S 3 is larger than the number of values in the file, the length of the data read from the file is the number of values in the file. The unit S 3 is a double word.  D : The initial device where the data is stored. 2. Instruction flags: 6_ 3. Related error codes (SR453): 6-737 Item Description Value unit Refer to operand C for its file format. If the file format is 0, 1, 3, 5 or 7, the unit of the value is a word. If the file format is 2, 4, or 6, the unit of the value is a double word.

Parameter unit The parameter unit is a double word. Usage The value in S1 must indicate a value in the file. If the value in S1 is 0, the instruction reads from the first value in the file. Flag Description SM450 ON: the memory card is in the CPU module SM451 The write protection switch on the memory card ON: the memory card is write protected. OFF: the memory card is not write protected. SM452 The data is being written from the PLC to the memory card, or the data is being read from the memory card into the PLC. SM453 ON: an error occurs during the operation of the memory card. If the flag is ON, you must reset it to OFF. The error code is stored in SR453.

Error code Description 16#005E An error occurs when the memory card is initialized. 16#005F The path is incorrect, or the file does not exist. 16#0060 The default folder cannot be created. 16#0061 The memory space is insufficient. 16#0062 The memory card is write protected. 16#0063 An error occurs when the data is written into the file.