Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

Chapter 6 Applied Instructions 3. Use S 3 to select the zero return mode. The function code is set by the two high and low16-bit parameters. See the following table for details. See the diagram below for mode setting. 6_ 6-779 Axis number Axis 1 Axis 2 Axis 3 Axis 4 Input point for S4 Can be any one of the input points X0–X7 and X10–X17. But the same input point cannot be selected for different axis output. If the DOG point shakes or the switch bounces, set the input point filter time in HWCONFIG.

Output point for D Y0 Y2 Y4 Y6 Direction output point Y1 Y3 Y5 Y7 Output mode SR462 SR482 SR502 SR522 Busy flag SM460 SM480 SM500 SM520 Completion flag SM461 SM481 SM501 SM521 Present output position SR460 SR461 SR480 SR481 SR500 SR501 SR520 SR521 S3: select the zero return mode High 16-bit Low 16-bit b31~b16 b15~b6 b5 b4 b3~b0 Number of pulses for motion reserved Direction setting*1 0: in the negative direction 1: in the positive direction Setting DOG signal 0: contact A 1: contact B Mode settig 0~15 (F) Number of Z phases Execute DZRN DOG signal received Move away frm DOG signal 0: stops immediately 2: moves a number of pulses and then stops Moves in the 3:

searches for a number of Z phases and then stop negative 4: outputs the clear signal Searches for direction 6: moves a number of pulses and outputs the the zero point clear signal in the 7: searches for a number of Z phases and outputs the clear signal direction of Moves in the negative or positive direction positive 1, 8, 9: stops immediately 10: moves a number of pulses and then stops 11: searches for a number of Z phases and then stop 5, 12, 13: outputs the clear signal 14: moves a number of pulses and outputs the clear signal 15: searches for a number of Z phases and outputs the clear signal 0: stops immediately 2: moves a number of pulses and then stops 3:

searches for a number of Z phases and then stop 4: outputs the clear signal 6: moves a number of pulses and outputs the clear signal 7: searches for a number of Z phases and outputs the clear signal 1, 8, 9: stops immediately 10: moves a number of pulses and then stops 11: searches for a number of Z phases and then stop 5, 12, 13: outputs the clear signal 14: moves a number of pulses and outputs the clear signal 15: searches for a number of Z phases and outputs the clear signal