Chapter 6 Applied Instructions DDRVI and DDRVA support the output devices for D 1 which can be the odd points as shown in the following table. Y2–Y10 as the high-speed output points. Only the Pulse+direction output mode is supported. It is not recommended that you use the input points Y0, 4. The output point for the pulse direction output device D 2 is affected by the scan cycle if it is not the recommended output point in the table above. 5. When D 2 uses the output mode Pulse+direction and S 1 has a minus sign, D 2 is ON. When S 1 has a plus sign, D 2 is OFF. D 2 is not OFF immediately after the pulse output in the negative direction is completed.
D 2 switches to OFF when the contact for the execution of the instruction is OFF. 6_ 6. For the instruction execution, you must use the parameters such as the start/end frequency and ramp-up/down time. Refer to the following table for SM/SR corresponding to the axes. The following table applies when D 1 selects the even output points as the output devices.
6-791 Axis number Axis 1 Axis 2 Axis 3 Axis 4 Output point for D1 Y0 Y2 Y4 Y6 Direction output point for D2 Y1 Y3 Y5 Y7 SR number SR462 SR482 SR502 SR522 Axis number Axis 7 Axis 8 Axis 9 Axis 10 Output point for D1 Y1 Y3 Y5 Y7 Direction output point for D2 Y120 or above or any M device (BOOL) Output point for D1 Y0 Y2 Y4 Y6 Busy flag SM460 SM480 SM500 SM520 Completion flag SM461 SM481 SM501 SM521 Reversing the output direction SM462 SM482 SM502 SM522 Stop flag SM463 SM483 SM503 SM523 Enabling S curve ramp-up/down SM468 SM488 SM508 SM528 Enabling fixed slope ramp-up/down SM469 SM489 SM509 SM529 Output completion auto-reset SM470 SM490 SM510 SM530 Executing an interrupt program when SM471 SM491 SM511 SM531 pulse output ends