Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

DVP-ES3 Series Programming Manual The following table applies when D 1 selects the odd output points as the output devices. _6 Some flags, such as S curve ramp-up/down, fixed slope ramp-up/down, and executing an interrupt program when pulse output ends, are not supported by the odd output points. If the output is ongoing, the preset output is the ramp-down stop when the instruction is disabled or stops temporarily. If the output must be stopped immediately, set the immediately stop flag to ON. 7. Added new SR652, SR653 for displaying number of pulse in ramp-up area and new SR654, SR655 for displaying number of pulse in ramp-down area.

6-792 Corresponding interrupt I number I500 I501 I502 I503 The output immediately stops when the SM476 SM496 SM516 SM536 instruction is disabled or stops Present output position SR460 SR461 SR480 SR481 SR500 SR501 SR520 SR521 Start/end frequency (Hz) SR463 SR483 SR503 SR523 Ramp-up time (ms) SR464 SR484 SR504 SR524 Ramp-down time (ms) SR465 SR485 SR505 SR525 Target frequency of the fixed slope SR472 SR473 SR492 SR493 SR512 SR513 SR532 SR533 S curve mode SR604 SR605 SR606 SR607 Present output frequency SR610 SR611 SR612 SR613 SR614 SR615 SR616 SR617 Output point for D1 Y1 Y3 Y5 Y7 Busy flag SM472 SM492 SM512 SM532 Completion flag SM473 SM493 SM513 SM533 Output stop flag SM474 SM494 SM514 SM534 Output completion auto-reset SM475 SM495 SM515 SM535 The output immediately stops when the SM477 SM497 SM517 SM537 instruction is disabled or stops Present output position SR474 SR475 SR494 SR495 SR514 SR515 SR534 SR535 Start/end frequency(Hz) SR476 SR496 SR516 SR536 Ramp-up/down time(ms) SR477 SR497 SR517 SR537