Mitsubishi — 5.1 List of Instructions

5 Categories & Use of Application Instructions DVP-PLC Application Manual 5-2 Mnemonic P Applicable to STEPS Category API Function 16-bit 32-bit instruction ES SA EH2 EH3 16-bit 32-bit High Speed Processing 50 REF -  Refresh     5 - 51 REFF -  Refresh and Filter Adjust -    3 - 52 MTR - - Input Matrix -    9 - 53 - DHSCS - High Speed Counter Set     - 13 54 - DHSCR - High Speed Counter Reset     - 13 55 - DHSZ - High Speed Zone Compare -    - 17 56 SPD - - Speed Detection     7 - 57 PLSY DPLSY - Pulse Y Output     7 13 58 PWM - - Pulse Width Modulation     7 - 59 PLSR DPLSR - Pulse Ramp     9 17 Handy Instructions 60 IST - - Initial State     7 - 61 SER DSER  Search a Data Stack -    9 17 62 ABSD DABSD - Absolute Drum Sequencer -    9 17 63 INCD - - Incremental Drum Sequencer -    9 - 64 TTMR - - Teaching Timer -    5 - 65 STMR - - Special Timer -    7 - 66 ALT -  Alternate State     3 - 67 RAMP DRAMP - Ramp Variable Value -    9 17 68 DTM - - Data Transform and Move -    9 - 69 SORT DSORT - Sort Tabulated Data -    11 21 Display of External Settings 70 TKY DTKY - Ten Key Input -    7 13 71 HKY DHKY - Hexadecimal Key Input -    9 17 72 DSW - - Digital Switch -    9 - 73 SEGD -  Seven Segment Decoder     5 - 74 SEGL - - Seven Segment with Latch     7 - 75 ARWS - - Arrow Switch -    9 - 76 ASC - - ASCII Code Conversion -    11 - 77 PR - - Print (ASCII Code Output) -    5 - Serial I/O 78 FROM DFROM  Read CR Data in Special Modules     9 17 79 TO DTO  Write CR Data into Special Modules     9 17 80 RS - - Serial Communication Instruction     9 - 81 PRUN DPRUN  Parallel Run -    5 9 82 ASCI -  Converts Hex to ASCII     7 - 83 HEX -  Converts ASCII to Hex     7 - 84 CCD -  Check Code -    7 - 85 VRRD -  Volume Read -    5 - 86 VRSC -  Volume Scale -    5 - 87 ABS DABS  Absolute Value     3 5 88 PID DPID - PID Control Loop     9 17 Basic Instructions 89 PLS - - Rising-edge Output     3 - 90 LDP - - Rising-edge Detection Operation     3 - 91 LDF - - Falling-edge Detection Operation     3 - 92 ANDP - - Rising-edge Series Connection     3 - 93 ANDF - - Falling-edge Series Connection     3 - 94 ORP - - Rising-edge Parallel Connection     3 - 95 ORF - - Falling-edge Parallel Connection     3 - 96 TMR - - 16-bit Timer     4 - 97 CNT DCNT - 16-bit / 32-bit Counter     4 6 98 INV - - Inverting Operation     1 - 99 PLF - - Falling-edge Output     3 - Communication 100 MODRD - - Read Modbus Data     7 - 101 MODWR - - Write Modbus Data     7 - 102 FWD - - Forward Running of VFD-A     7 - 103 REV - - Reverse Running of VFD-A     7 - 104 STOP - - Stop VFD-A     7 - 105 RDST - - Read VFD-A Status     5 - 106 RSTEF - - Reset Abnormal VFD-A     5 -