2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-47 ES SA Off STOP RUN Special EH2 EH3 Function EX SX Attribute Latched Default M SV SV2 SS SC On RUN STOP M1305 Reverse operation of the 1st group pulse CH0 (Y0, Y1) for PLSV/DPLSV/DRVI/DDRVI/DRVA/DDRVA instruction ╳ ╳ ○ ○ Off - - R NO Off M1306 Reverse operation of the 2nd group pulse CH1 (Y2, Y3) for PLSV/DPLSV/DRVI/DDRVI/DRVA/DDRVA instruction ╳ ╳ ○ ○ Off - - R NO Off M1308 Off->On: The 1st pulse group CH0 (Y0, Y1) high-speed output immediately stops. On->Off: Completing remaining number of output pulses ╳ ╳ ○ ○ Off Off Off R/W NO Off M1309 Off->On: The 1st pulse group CH1 (Y2, Y3) high-speed output immediately stops.
On->Off: Completing remaining number of output pulses ╳ ╳ ○ ○ Off Off Off R/W NO Off M1310* Disabling Y10 pulse output (for SC V1.4 and above) (Not available in SX V3.0 and above) ╳ ○ ╳ ╳ Off Off - R/W NO Off Off->On: The 1st pulse group CH2 (Y4, Y5) high-speed output immediately stops. On->Off: Completing remaining numbe of output pulses ╳ ╳ ○ ○ Off Off Off R/W NO Off M1311* Disabling Y11 pulse output (for SC V1.4 and above) (Not available in SX V3.0 and above) ╳ ○ ╳ ╳ Off Off - R/W NO Off Off->On: The 1st pulse group CH3 (Y6, Y7) high-speed output immediately stops. On->Off:
Completing remaining number of output pulses ╳ ╳ ○ ○ Off Off Off R/W NO Off M1312 Controlling start input point of C235 ╳ ╳ ○ ╳ Off - - R/W NO Off Sending request of COM1 (RS-232) communication instruction (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R/W NO Off M1313 Controlling start input point of C236 ╳ ╳ ○ ╳ Off - - R/W NO Off Waiting to receive the data of COM1 (RS-232) communication instruction is completed (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R NO Off M1314 Controlling start input point of C237 ╳ ╳ ○ ╳ Off - - R/W NO Off Receiving the data of COM1 (RS-232) communication instruction is completed (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R/W NO Off M1315 Controlling start input point of C238 ╳ ╳ ○ ╳ Off - - R/W NO Off An error occurs when receiving the data of COM1 (RS-232) communication instruction (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R/W NO Off M1316 Controlling start input point of C239 ╳ ╳ ○ ╳ Off - - R/W NO Off Sending request of COM3 (RS-485) communication instruction (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R/W NO Off M1317 Controlling start input point of C240 ╳ ╳ ○ ╳ Off - - R/W NO Off Waiting to receive the data of COM3 (RS-485) communication instruction is completed (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R NO Off M1318 Receiving data of COM3 (RS-485) communication instruction is completed (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R/W NO Off M1319 An error occurs when receiving the data of COM3 (RS-485) communication instruction (only available in the instructions MODRW and RS) ╳ ╳ ╳ ○ Off Off - R/W NO Off