2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-48 ES SA Off STOP RUN Special EH2 EH3 Function EX SX Attribute Latched Default M SV SV2 SS SC On RUN STOP M1320 Controlling reset input point of C235 ╳ ╳ ○ ╳ Off - - R/W NO Off Slave mode: COM3 (RS-485) is in the ASCII/RTU mode. (Off: ASCII mode; On: RTU mode) Master mode: COM3 (RS-485) is in the ASCII/RTU mode. (Off: Off: ASCII mode; On: RTU mode) M1320 is used with the instruction MODRW/FWD.
╳ ╳ ╳ ○ Off - - R/W NO Off M1321 Controlling reset input point of C236 ╳ ╳ ○ ╳ Off - - R/W NO Off M1322 Controlling reset input point of C237 ╳ ╳ ○ ╳ Off - - R/W NO Off M1323 Controlling reset input point of C238 ╳ ╳ ○ ╳ Off - - R/W NO Off M1324 Controlling reset input point of C239 ╳ ╳ ○ ╳ Off - - R/W NO Off M1325 Controlling reset input point of C240 ╳ ╳ ○ ╳ Off - - R/W NO Off M1328 Enabling start/reset of C235 ╳ ╳ ○ ╳ Off - - R/W NO Off M1329 Enabling start/reset of C236 ╳ ╳ ○ ╳ Off - - R/W NO Off M1330 Enabling start/reset of C237 ╳ ╳ ○ ╳ Off - - R/W NO Off M1331 Enabling start/reset of C238 ╳ ╳ ○ ╳ Off - - R/W NO Off M1332 Enabling start/reset of C239 ╳ ╳ ○ ╳ Off - - R/W NO Off M1333 Enabling start/reset of C240 ╳ ╳ ○ ╳ Off - - R/W NO Off M1334* EH2/SV/EH3/SV2:
stopping the 1st group pulse output CH0 (Y0, Y1) SC V1.4 and above: selecting Y10 pulse output stop modes (Not available in SX V3.0 and above) ╳ ○ ○ ○ Off - - R/W NO Off M1335* EH2/SV/EH3/SV2: stopping the 2nd group pulse output CH1 (Y2, Y3) SC V1.4 and above:
selecting Y11 pulse output stop modes (Not available in SX V3.0 and above) ╳ ○ ○ ○ Off - - R/W NO Off M1336 Sending out the 1st group pulse output CH0 (Y0, Y1) ╳ ╳ ○ ○ Off Off Off R NO Off M1337 Sending out the 2nd group pulse output CH1 (Y2, Y3) ╳ ╳ ○ ○ Off Off Off R NO Off M1338 Enabling offset pulses of the 1st group pulse output CH0 (Y0, Y1) ╳ ╳ ○ ○ Off - - R/W NO Off M1339 Enabling offset pulses of the 2nd group pulse output CH1 (Y2, Y3) ╳ ╳ ○ ○ Off - - R/W NO Off M1340 Generating interruption I110 after the 1st group pulse output CH0 (Y0, Y1) is sent out ╳ ╳ ○ ○ Off - - R/W NO Off M1341 Generating interruption I120 after the 2nd group pulse output CH1 (Y2, Y3) is sent out ╳ ╳ ○ ○ Off - - R/W NO Off M1342 Generating interruption I130 when the 1st group pulse output CH0 (Y0, Y1) is sent out ╳ ╳ ○ ○ Off - - R/W NO Off M1343 Generating interruption I140 when the 2nd group pulse output CH1 (Y2, Y3) is sent out ╳ ╳ ○ ○ Off - - R/W NO Off M1344 Enabling the offset of the 1st group pulse output CH0 (Y0, Y1) ╳ ╳ ○ ○ Off - - R/W NO Off M1345 Enabling the offset of the 2nd group pulse output CH1 (Y2, Y3) ╳ ╳ ○ ○ Off - - R/W NO Off M1346 Enabling ZRN CLEAR output signal ╳ ╳ ○ ○ Off - - R/W NO Off M1347 EH2/SV/EH3/SV2:
Reset after the 1st group pulse output CH0 (Y0, Y1) is completed. SA/SX/SC: Automatic zero return after Y0 high-speed pulse output is completed. ╳ ○ ○ ○ Off - - R/W NO Off M1348 EH2/SV/EH3/SV2: Reset after the 2nd group pulse output CH1 (Y2, Y3) is completed. SA/SX/SC: Automatic zero return after Y1 high-speed pulse output is completed. ╳ ○ ○ ○ Off - - R/W NO Off M1350* Enabling PLC LINK ╳ ○ ○ ○ Off - Off R/W NO Off M1351* Enabling auto mode on PLC LINK ╳ ○ ○ ○ Off - - R/W NO Off M1352* Enabling manual mode on PLC LINK ╳ ○ ○ ○ Off - - R/W NO Off