Mitsubishi — 2.10 Special Auxiliary Relays and Special Data Registers

2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-68 ES SA Off STOP RUN EH2 EH3 Special D Function EX SX    Attribute Latched Default SV SV2 SS SC On RUN STOP D1450* Data length to be written on Slave ID#1 ╳ ○ ○ ○ - - - R/W YES 16 D1451* Data length to be written on Slave ID#2 ╳ ○ ○ ○ - - - R/W YES 16 D1452* Data length to be written on Slave ID#3 ╳ ○ ○ ○ - - - R/W YES 16 D1453* Data length to be written on Slave ID#4 ╳ ○ ○ ○ - - - R/W YES 16 D1454* Data length to be written on Slave ID#5 ╳ ○ ○ ○ - - - R/W YES 16 D1455* Data length to be written on Slave ID#6 ╳ ○ ○ ○ - - - R/W YES 16 D1456* Data length to be written on Slave ID#7 ╳ ○ ○ ○ - - - R/W YES 16 D1457* Data length to be written on Slave ID#8 ╳ ○ ○ ○ - - - R/W YES 16 D1458* Data length to be written on Slave ID#9 ╳ ○ ○ ○ - - - R/W YES 16 D1459* Data length to be written on Slave ID#10 ╳ ○ ○ ○ - - - R/W YES 16 D1460* Data length to be written on Slave ID#11 ╳ ○ ○ ○ - - - R/W YES 16 D1461* Data length to be written on Slave ID#12 ╳ ○ ○ ○ - - - R/W YES 16 D1462* Data length to be written on Slave ID#13 ╳ ○ ○ ○ - - - R/W YES 16 D1463* Data length to be written on Slave ID#14 ╳ ○ ○ ○ - - - R/W YES 16 D1464* Data length to be written on Slave ID#15 ╳ ○ ○ ○ - - - R/W YES 16 D1465* Data length to be written on Slave ID#16 ╳ ○ ○ ○ - - - R/W YES 16 D1466 Number of pulses required per revolution of motor at CH0 (low word) ╳ ╳ ○ ○ - - - R YES 2,000 D1467 Number of pulses required per revolution of motor at CH0 (high word) ╳ ╳ ○ ○ - - - R YES 0 D1468 Number of pulses required per revolution of motor at CH1 (low word) ╳ ╳ ○ ○ - - - R YES 2,000 D1469 Number of pulses required per revolution of motor at CH1 (high word) ╳ ╳ ○ ○ - - - R YES 0 D1470 Distance created for 1 revolution of motor at CH0 (low word) ╳ ╳ ○ ○ - - - R YES 1,000 D1471 Distance created for 1 revolution of motor at CH0 (high word) ╳ ╳ ○ ○ - - - R YES 0 D1472 Distance created for 1 revolution of motor at CH1 (low word) ╳ ╳ ○ ○ - - - R YES 1,000 D1473 Distance created for 1 revolution of motor at CH1 (high word) ╳ ╳ ○ ○ - - - R YES 0 D1474 Machine unit of CH0 movement (low word) ╳ ╳ ○ ○ - - - R YES 0 D1475 Machine unit of CH0 movement (high word) ╳ ╳ ○ ○ - - - R YES 0 D1476 Machine unit of CH1 movement (low word) ╳ ╳ ○ ○ - - - R YES 0 D1477 Machine unit of CH1 movement (high word) ╳ ╳ ○ ○ - - - R YES 0 D1478 Output/input ratio of CH2 close-loop control (for EH2/SV/EH3/SV2) ╳ ╳ ○ ○ 100 - - R/W NO 100 D1479 Output/input ratio of CH3 close-loop control (for EH2/SV/EH3/SV2) ╳ ╳ ○ ○ 100 - - R/W NO 100 D1480* ↓ D1495* Data which is read from slave ID#1 in the PLC LINK at the time when M1353 is OFF Initial data register where the data read from slave ID#1~ID#16 in the PLC LINK is stored at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1496* ↓ D1511* Data which is written into slave ID#1 in the PLC LINK at the time when M1353 is OFF Initial data register where the data written into slave ID#1~ID#16 in the PLC LINK is stored at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1512* ↓ D1527* Data which is read from slave ID#2 in the PLC LINK at the time when M1353 is OFF Initial communication address where the data read from slave ID#17~ID#32 in the PLC LINK is stored at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0