2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-69 ES SA Off STOP RUN EH2 EH3 Special D Function EX SX Attribute Latched Default SV SV2 SS SC On RUN STOP D1528* ↓ D1543* Data which is written into slave ID#2 in the PLC LINK at the time when M1353 is OFF Initial communication address where the data written into slave ID#17~ID#32 in the PLC LINK is stored at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1544* ↓ D1559* Data which is read from slave ID#3 in the PLC LINK at the time when M1353 is OFF Number of data read from slave ID#17~ID#32 in the PLC LINK at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1560* ↓ D1575* Data which is written into slave ID#3 in the PLC LINK at the time when M1353 is OFF Number of data written into slave ID#17~ID#32 in the PLC LINK at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1576* ↓ D1591* Data which is read from slave ID#4 in the PLC LINK at the time when M1353 is OFF Initial data register where the data read from slave ID#17~ID#32 in the PLC LINK is stored at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1592* ↓ D1607* Data which is written into slave ID#4 in the PLC LINK at the time when M1353 is OFF Initial data register where the data written into slave ID#17~ID#32 in the PLC LINK is stored at the time when M1353 is ON (For EH2/SV/EH3/SV2) (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1608* ↓ D1623* Data which is read from slave ID#5 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1624* ↓ D1639* Data which is written into slave ID#5 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1640* ↓ D1655* Data which is read from slave ID#6 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1656* ↓ D1671* Data which is written into slave ID#6 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1672* ↓ D1687* Data which is read from slave ID#7 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1688* ↓ D1703* Data which is written into slave ID#7 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1704* ↓ D1719* Data which is read from slave ID#8 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1720* ↓ D1735* Data which is written into slave ID#8 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0 D1736* ↓ D1751* Data which is read from slave ID#9 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R YES 0 D1752* ↓ D1767* Data which is written into slave ID#9 in the PLC LINK (They are non-latched data registers in SX V3.0 and above.) ╳ ○ ○ ○ - - - R/W YES 0