Delta — 4.1 Table of Control Registers

DVP201/202/211LC-SL Load Cell Module Operation Manual 4.1 Table of Control Registers 4-2 CR# Address Attribute Register name Explanation #0 H1000 O R Model name The model code of a load cell module is defined by the module’s system. DVP201LC-SL’s model code=H’5106 DVP202LC-SL’s model code=H’5206 DVP211LC-SL’s model code=H’5906 #1 H1001 O R Firmware version Hexadecimal value The current firmware version of a load cell module is displayed. #2 H1002 O R/W Characteristic value CH1: Bit 0~bit 7; CH2: Bit 8~bit 15 Mode 0: 1 mV/V; Mode 4: 20 mV/V Mode 1: 2 mV/V; Mode 5: 40 mV/V Mode 2: 4 mV/V; Mode 6: 80 mV/V Mode 3: 6 mV/V #3 H1003 O R/W Reaction time for measurement CH1: bit0~bit7; CH2:

bit8~bit15 Mode 0: 2.5ms; Mode 5: 60ms Mode 1: 10ms; Mode 6: 100ms Mode 2: 16ms; Mode 7: 200ms Mode 3: 20ms; Mode 8: 400ms Mode 4: 50ms (factory setting) #6 H1006 X R/W Returning to zero/Subtracting a tare K1: Subtracting the tare measured by CH1 K2: Not subtracting the tare measured by CH1 K3: Restoring the weight measured by CH1 to zero K4: Subtracting the tare measured by CH2 K5: Not subtracting the tare measured by CH2 K6: Restoring the weight measured by CH2 to zero #7 H1007 O R/W Displaying a gross weight/net weight CH1: Bit 0~bit 7; CH2: Bit 8~bit 15 K0: Displaying a gross weight K1:

Displaying a net weight #8 H1008 X R/W Tare measured by CH1 (Low word) Displaying a tare #9 H1009 X R/W Tare measured by CH1 (High word)