Chapter 4 Control Registers 4-3 CR# Address Attribute Register name Explanation #10 H100A X R/W Tare measured by CH2 (Low word) #11 H100B X R/W Tare measured by CH2 (High word) #12 H100C X R Weight measured by CH1 (Low word) Displaying a weight #13 H100D X R Weight measured by CH1 (High word) #14 H100E X R Weight measured by C2 (Low word) #15 H100F X R Weight measured by C2 (High word) #16 H1010 O R/W Number of weights measured by CH1 in a stability range Setting range: K1~K500 (Factory setting: K5) #17 H1011 O R/W Number of weights measured by CH2 in a stability range Setting range: K1~K500 (Factory setting: K5) #18 H1012 O R/W Stability range for CH1 Setting range:
K1~K10000 (Factory setting: K10) #19 H1013 O R/W Stability range for CH2 Setting range: K1~K10000 (Factory setting: K10) #20 H1014 O R/W Lower limit of the zero return for CH1 Once the weight is in this setting range K-1 ~ K-32768, the status is on-load on the load cell. (Factory setting: K-10) #21 H1015 O R/W Lower limit of the zero return for CH2 #25 H1019 O R/W Total number of points which need to be adjusted Setting range: K2~K20 (Factory setting: K2) #26 H101A X R/W Adjustment command CH1: K1~K20 CH2:
K21~K40 #27 H101B X R/W Selecting a point which needs to be adjusted for CH1 K1~K19 #28 H101C X R/W Selecting a point which needs to be adjusted for CH2 K1~K19 #29 H101D O R/W Digital value given to a point which needs to be adjusted for CH1 (Low word) Digital value given to a point which needs to be adjusted #30 H101E O R/W Digital value given to a point which needs to be adjusted for CH1 (High word) #31 H101F O R/W Digital value given to a point which needs to be adjusted Digital value corresponding to a weight needs to be