DVS Series Managed Industrial Ethernet Switches User’s Manual LLDP Basic Settings 3.13.1.2 LLDP Interface Configuration You can configure LLDP settings for an individual interface in this page. Interface Settings 3-116 Description Factory Default LLDP Status Specify the status of STP on the switch: Enable: LLDP is enabled. You can configure LLDP, and the settings take effect after you have applied them. Disable: LLDP is disabled. You can still configure LLDP, but the settings do not take effect after you have applied them. Enable Transmit Interval (8 to 32768) Enter the interval in seconds to transmit the LLDP frames. Enter a number in the range of 5 to 32768 seconds.
30 Holdtime Multiplier Enter the hold time multiplier in seconds. The hold time multiplier multiplies the transmit interval to define the Time to Live (TTL) period. Enter a number in the range of 2 to 10 seconds. 4 Reinitialization Delay Enter the delay in seconds before reinitialization. Enter a number in the range of 1 to 10 seconds. A longer time prevents frequent reinitializations. 2 Notification Interval Enter the interval in seconds for the transmission of notifications. Enter a number in the range of 5 to 3600 seconds. 5 Description Factory Default Port This field displays the interface number. interface number