Delta Electronics DVS — B.1 MODBUS TCP Map

DVS Series Managed Industrial Ethernet Switches User’s Manual B-6 Address Offset Data Type Description SPF DDM Information 0x4000 1 word Port 1 to Port 3 Port No. 0x4100 20 words Port 1 to Port 3 Model Name Example:

LCP-1250B4QDRH Word 0 Hi byte = 'L' Word 0 Lo byte = 'C' Word 1 Hi byte = 'P' Word 1 Lo byte = '-' Word 2 Hi byte = '1' Word 2 Lo byte = '2' Word 3 Hi byte = '5' Word 3 Lo byte = '0' Word 4 Hi byte = 'B' Word 4 Lo byte = '4' Word 5 Hi byte = 'Q' Word 5 Lo byte = 'D' Word 6 Hi byte = 'R' Word 6 Lo byte = 'H' Word 7 Hi byte = '\0' Word 7 Lo byte ='\0' 0x4200 2 words Port 1 to Port 3 Temperature Word 0 = Temperature MSB Word 1 = Temperature LSB 0x4300 2 words Port 1 to Port 3 Voltage Word 0 = Vcc MSB Word 1 = Vcc LSB 0x4400 2 words Port 1 to Port 3 TX Power Word 0 = TX Power MSB Word 1 = TX Power LSB 0x4500 2 words Port 1 to Port 3 RX Power Word 0 = RX Power MSB Word 1 = RX Power LSB 0x4600 1 words Port 1 to Port 3 Link Status 0x0000:

Link down 0x0001: Link up Alarm 0x5000 1 word Switch cold start alarm 0x0000: OFF 0x0001: ON 0xFFFF: Disable 0x5001 1 word Switch warm start alarm 0x0000: OFF 0x0001: ON 0x5004 1 word Power state on alarm 0x0000: OFF 0x0001: ON 0x5005 1 word Power state off alarm 0x0000: OFF 0x0001: ON