Appendix B MODBUS TCP Map B-7 Address Offset Data Type Description 0x5006 1 word DI on alarm 0x0000: OFF 0x0001: ON 0x5007 1 word DI off alarm 0x0000: OFF 0x0001: ON 0x5008 1 word authentication failure alarm 0x0000: OFF 0x0001: ON 0x5009 1 word dot1d Bridge New Root alarm 0x0000: OFF 0x0001: ON 0x500A 1 word dot1d Bridge Topology Changed alarm 0x0000: OFF 0x0001: ON 0x500B 1 word LLDP Remote Tables Change alarm 0x0000: OFF 0x0001: ON 0x500C 1 word Configuration Changed alarm 0x0000: OFF 0x0001: ON 0x500D 1 word Firmware update alarm 0x0000: OFF 0x0001: ON 0x500E 1 word IP changed alarm 0x0000: OFF 0x0001: ON 0x500F 1 word Password changed alarm 0x0000: OFF 0x0001:
ON 0x5100 ~ 0x5102 1 word SFP Port 1 to Port 3 DDM Failure - Temp alarm 0x0000: OFF 0x0001: ON 0x5110 ~ 0x5112 1 word SFP Port 1 to Port 3 DDM Failure – Voltage 0x0000: OFF 0x0001: ON 0x5120 ~ 0x5122 1 word SFP Port 1 to Port 3 DDM Failure – Bias 0x0000: OFF 0x0001: ON 0x5130 ~ 0x5132 1 word SFP Port 1 to Port 3 DDM Failure - TX Power 0x0000: OFF 0x0001: ON 0x5140 ~ 0x5142 1 word SFP Port 1 to Port 3 DDM Failure - RX Power 0x0000: OFF 0x0001: ON