sinee — 2.5.1 Motor installation

EA180 Series Servo Drive Users Manual  Places without high-temperature devices  Places free of water droplets, vapor, dust or oily dust  Places free of corrosive or flammable gases or liquids  Places free of floating dust or metal particles  Firm places without vibration or electromagnetic noise interference. 2.4 Installation direction and space of servo drive Refer to Chapter 11 for outer dimensions and weight of servo drives and servo motors. 2.4.1 Method Please ensure that the installation direction is perpendicular to the wall. Use natural convection or a cooling fan to cool the servo drive. Fix the servo drive firmly on the mounting surface through the mounting holes.

When installing, ensure that the front side of the servo drive (the actual installation surface of the operator) faces the operator and make it perpendicular to the wall. 2.4.2 Cooling In order to ensure air convection, please refer to Fig. 2-1 and leave enough space around the servo drive. In order to prevent local high temperature in the operating environment of the servo drive, it is necessary to keep uniform temperature in the electric cabinet. Please be sure to install a cooling fan above the servo drive in the electric cabinet. 2.4.3 Grounding Please be sure to ground the grounding terminal, otherwise an electric shock or misoperation due to interference may be caused.

Air outlet Air outlet Air outlet Air outlet 50mm above CN4 CN5 IN CN3 OUT CN2 CN6 CN4 CN5 IN CN3 OUT CN2 CN6 CN4 CN5 IN CN3 OUT CN2 CN6 CN4 CN5 IN CN3 OUT CN2 CN6 CHARGE 10mm above 50mm above 20mm above Air inlet Air inlet Air inlet Air inlet Figure 2-1 Installation space of servo drive 2.5 Installation direction and space of servo motor 2.5.1 Motor installation Servo motors must be properly installed on a dry and strong platform. Please maintain good ventilation and cooling circulation during installation, and keep proper grounding. Please refer to "Chapter 11 Specifications" for the outer dimensions and weight of the motors. 15 CHARGE CHARGE CHARGE