* This parameter will be saved and immediately activated (ON) when the system is powered on next time. If this is not desired, please set the parameter value to 0 before power-off.

70 Technical Manual for EA190 Series Servo Driver V100 AF-00 Reset by software Data size 16bit Communication address 3F00H Register value storage Automatic zeroing upon completion Register value Keyboard display Operation 0 Press the key to display , without any operation 1 Press the key for resetting by software (equivalent to switching on the control power) AF-01 Alarm reset Data size 16bit Communication address 3F01H Register value storage Automatic zeroing upon completion Register value Keyboard display Operation 0 Press the key to display , without any operation 1 Press the key to execute an alarm resetting operation * It must be a resettable alarm and the cause of the current alarm has been eliminated.

AF-02 JOG function Data size 16bit Communication address 3F02H Register value storage - Register value Keyboard display Operation - Press the key, and the motor runs forward, displaying ; press the key, and the motor runs reversely, displaying . When no key is pressed, the motor stands still, displaying * The jog running speed is determined by P8-00, and the acceleration and deceleration time is determined by P8-01. * Jog running occurs in the (inactivated and ready) state; if a warning occurs during jog running, the system will automatically exit from the mode.

AF-03 Internal S ON command _ Data size 16bit Communication address 3F03H Register value storage Save Register value Keyboard display Operation 0 Press to display ; if there is no other activation input, the driver will enter the OFF state 1 If the activation conditions are satisfied, press to display and the driver will enter the ON state.