sinee — 7.2Table of functional parameters

72 Technical Manual for EA190 Series Servo Driver V100 AF-08 Display of non-default setting Data size 16bit Communication address 3F08H Register value storage Automatic zeroing upon power-on Register value Keyboard display Operation 0 Press to display , and it displays normally 1 Press to display , and then press to enter the modified parameter mode; the difference from normal function code display is that there is “-” flashing in the middle. Press or to view modified parameters in sequence; press to view modified values.

AF-09 System parameter initialization Data size 16bit Communication address 3F09H Register value storage Automatic zeroing upon power-on Register value Keyboard display Operation 1 If AF-09≠65535, press to display , without any operation 65535 If AF-09 = 65535, press to display , and restore the factory setting of the function code. Caution☞ 1: When this function is used, it is required to turn on the control power. 2:

This operation will not restore the motor parameters AF-10 Display of motor group parameters Data size 16bit Communication address 3F0AH Register value storage Automatic zeroing upon power-on Register value Keyboard display Operation 0 Press to display , with parameters of the Pd group hidden 1 Press to display , with parameters of the Pd group shown AF-15 Parameter reading of motor with serial encoder Data size 16bit Communication address 3F0FH Register value storage Automatic zeroing upon power-on Register value Keyboard display Operation 0 Press the key to display , without any operation 1 Press to display ; read and use motor parameter data stored in the serial encoder.

If no data is read, the originally set motor parameters of group Pd will be used.