sinee — 7.2Table of functional parameters

82 Technical Manual for EA190 Series Servo Driver V100 gear ratio 22 ORGP External detector input 23 SHOM Homing 24 TL2 External torque limit 25 EMGS Emergency stop 28 CMD SEL _ Speed source switching 33 PDIR SEL _ Direction selection for position command 34 GBK Position probe 35 PUL UP _ Forward pulse deviation 36 PUL DN _ Reverse pulse deviation 48 SPD CTR1 _ Speed mode start and stop control - forward direction 49 SPD CTR2 _ Speed mode start and stop control - reverse direction P6-10 DI forced valid 00000000B~11111111B 0: Depending on the terminal status; 1: forced valid U16 0000 0000B - P S T 〇 060AH P6-11 DO level logic 00000B~11111B 0: Positive logic; 1:

Negative logic U16 00000B - P S T 〇 060BH P6-12 DO1 function number Value Item Function name U16 1 - P S T ● 060CH P6-13 DO2 function number 0 Disable Terminal inactive U16 2 - P S T ● 060DH P6-14 DO3 function number 1 S-RDY Servo ready U16 8 - P S T ● 060EH P6-15 DO4 function number 2 BK Brake control P S T 3 TGON Motor rotation 4 ZER0 Zero speed of motor 5 V-CLS Speed reached 6 V-CMP Speed consistency 7 PNEAR Positioning approach U16 12 - ▲ 060FH 8 COIN Positioning completion 9 C-LT Torque limit 10 V-LT Rotating speed limit 11 WARN Warning output 12 ALM Alarm output 13 Tcmp Torque consistency