Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Caution ☞ 1: When this function is used, it is required to turn on the control power. 2: This operation will not restore the motor parameters 84 Communication Data size 16bit 3F08H address Display of non-default setting Register value Automatic zeroing upon power-on storage Register Keyboard Operation value display 0 Press to display , and it displays normally Press to display , and then press to enter the modified parameter mode; the difference from normal function code display is that there is “-” flashing in the middle. 1 Press or to view modified parameters in sequence; press to view modified values.

Data size 16bit Communication address 3F08H Register value storage Automatic zeroing upon power-on Keyboard display Operation Press to display , and it displays normally Press to display , and then press to enter the modified parameter mode; the difference from normal function code display is that there is “-” flashing in the middle. Press or to view modified parameters in sequence; press to view modified values.

System parameter initialization Data size 16bit Communication address 3F09H Register value storage Automatic zeroing upon power-on Register value Keyboard display Operation 0 If AF-09≠65535, press to display , without any operation 65535 If AF-09=65535, press to display , and restore the factory setting of the function code.

Display of motor group parameters Data size 16bit Communication address 3F0AH Register value storage Automatic zeroing upon power-on Register value Keyboard display Operation 0 Press to display , with parameters of the Pd group hidden 1 Press to display , with parameters of the Pd group shown Parameter reading of motor with serial encoder Data size 16bit Communication address 3F0FH Register value storage Automatic zeroing upon power-on Register value Keyboard display Operation 0 Press to display , with parameters of the Pd group hidden 1 Press to display ; read and use motor parameter data stored in the serial encoder.

If no data is read, the originally set motor parameters of group Pd will be used. Absolute type encoder multiple-turn data and alarm processing Data size 16bit Communication address 3F10H Register value storage Automatic zeroing upon completion Register value Keyboard display Operation 0 Press the key to display , without any operation 1 Clear multiple-turn encoder alarm: Press to display , and execute corresponding operation 2 Clear multiple-turn data and alarm of multiple-turn encoder: Press to display , and execute corresponding operation Important: This function can only be operated in the inactivated state