EF1 Drain filter blocked (drain phase too long) Drain tube blocked/kinked/too high; Drain filter dirty/blocked. EF2 Excessive detergent dosing (excessive foam during draining) Excessive detergent dosing; drain tube kinked/blocked; Drain filter dirty/blocked. EF3 Aqua control intervention Water leaks onto base frame; water control system defective. EF4 Water fill pressure low, no signal of flowmeter and solenoid valve open Tap closed; water fill pressure low. EF5 Unbalanced load Final spin phases skipped. EF6 Reset ---------------- EH1 Frequency power of appliance out of limits Power supply problems (incorrect / disturbance); PCB faulty.
EH2 Voltage too high Power supply problems (incorrect / disturbance); PCB faulty. EH3 Voltage too low Power supply problems (incorrect / disturbance); PCB faulty. EHE Incongruence between safety relay (in the PCB) and the safety “sensing” circuit Wiring faulty; PCB faulty. EHF Safety “sensing” circuit faulty (input voltage to microprocessor wrong) PCB faulty. 3.5.1 Notes concerning certain alarm codes ѓ Configuration alarms E93:
If this alarm is generated (when the appliance is switched on), operation of the appliance is blocked, the LEDs placed above or inside the START/PAUSE button start to flash displaying the complete codification (family plus alarm), the display shows the alarm code on condition that the configuration part of the display is ok. The diagnostic procedure cannot be accessed; the only option is to switch the appliance OFF. ѓ Configuration alarm E94: displayed. It is not possible to enter the diagnostics or to use the mode “rapid displaying of the alarm”. ѓ Alarms EH1(Eb1)-EH2(Eb2)-EH3(Eb3): restored to the correct value or the appliance is switched off (programme selector on “0”).
The family of alarm “b or H” operation of the appliance, while the family plus the alarm are displayed if the problem occurs at the switching on, through the flashing of the LEDs placed above or inside the START/PAUSE button. At the same time the code is represented also in the display. It is not possible to enter the diagnostics or to use the mode “rapid displaying of the alarm”: the complete alarm can be read only when the abnormal situation has terminated. ѓ Alarms E51- E52: button (INPUT styling).
QUICK GUIDE AND APPLIANCES LIST 49/176 Alarm Possible fault Action/machine status ENV06 EWM11xx EWM21xx EWM25xx/35xx Alarm Possible fault Action/machine status Reset Alarm EF1 Drain filter blocked (drain phase too long) Drain tube blocked/kinked/too high; Drain filter dirty/blocked. Warning displayed at the end of cycle (specific LED). START/RESET EF2 Excessive detergent dosing (excessive foam during draining) Excessive detergent dosing; drain tube kinked/blocked; Drain filter dirty/blocked. Warning displayed after 5 attempts or by the specific LED. RESET EF3 Aqua control intervention Water leaks onto base frame; water control system defective. Water drain.
ON/OFF RESET EF4 Water fill pressure low, no signal of flowmeter and solenoid valve open Tap closed; water fill pressure low. ---------------- RESET EF5 Unbalanced load Final spin phases skipped. ---------------- RESET EF6 Reset ---------------- No action to be performed, if continues replace the PCB. ---------------- EH1 Frequency power of appliance out of limits Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON EH2 Voltage too high Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON EH3 Voltage too low Power supply problems (incorrect / disturbance); PCB faulty.
Wait for frequency nominal conditions. OFF/ON EHE Incongruence between safety relay (in the PCB) and the safety “sensing” circuit Wiring faulty; PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET EHF Safety “sensing” circuit faulty (input voltage to microprocessor wrong) PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET