E82 Error in selector reset position E83 Error in selector reading E91 Communication error between PCB and display board PCB faulty. E93 Incorrect configuration of appliance E94 Incorrect configuration of washing cycle E95 Communication error between microprocessor and EEPROM PCB faulty. E97 Incongruence between programme selector and cycle configuration E98 Communication error between main board - Inverter E9H Communication error between microprocessor and FLASH memory Display board. E9C Machine configuration error Display board. E9d Clock faulty Display board.
E9F Communication error between PCB and remote devices EA1 Drum positioning (DSP) faulty EA6 DSP door opening faulty EC1 Solenoid valve blocked with flowmeter working EC3 Problems with Weight sensor (no signal or out of limits) Ed1 Data communication error between WD board and PCB Ed2 Drying heating element relay 1 faulty Ed3 Drying heating element relay 2 faulty Ed4 Relay which commutates power between washing heating element and drying (in the WD board) Ed6 No communication between PCB and display board (INPUT) QUICK GUIDE AND APPLIANCES LIST Alarm Possible fault ENV06 EWM11xx EWM21xx EWM25xx/35xx E92 Communication incongruence between main PCB- display board (versions not compatible) Alarm Possible fault Action/machine status Reset Alarm E82 Error in selector reset position PCB faulty (Wrong configuration data).
---------------- RESET E83 Error in selector reading PCB faulty (Wrong configuration data. Cycle cancelled. START/RESET E91 Communication error between PCB and display board Wiring faulty; Control/display board faulty: PCB faulty. ---------------- RESET E92 Communication incongruence between main PCB- display board (versions not compatible) Wrong control/display board; Wrong PCB (do not correspond to the model). Cycle interrupted. OFF/ON E93 Incorrect configuration of appliance PCB faulty; (Incorrect configuration data). Cycle interrupted. OFF/ON E94 Incorrect configuration of washing cycle PCB faulty; (Incorrect configuration data). Cycle interrupted.
OFF/ON E95 Communication error between microprocessor and EEPROM PCB faulty. Cycle interrupted. RESET E97 Incongruence between programme selector and cycle configuration Faulty PCB (Wrong configuration data). Cycle interrupted. RESET E98 Communication error between main board - Inverter Incompatibility between main board and Inverter. Cycle interrupted. OFF/ON E9H Communication error between microprocessor and FLASH memory Display board. ---------------- OFF/ON RESET E9C Machine configuration error Display board. ---------------- OFF/ON RESET E9d Clock faulty Display board.
---------------- OFF/ON RESET E9F Communication error between PCB and remote devices Wiring between PCB and Inverter faulty; PCB faulty; Inverter faulty. Cycle interrupted. OFF/ON EA1 Drum positioning (DSP) faulty Motor belt broken; Wiring faulty; PCB faulty; DSP sensor faulty. Positioning phase skipped. ON/OFF RESET EA6 DSP door opening faulty Motor belt broken; Wiring faulty; Drum cover open. Motor faulty; PCB faulty. Cycle paused. ON/OFF RESET EC1 Solenoid valve blocked with flowmeter working Wiring faulty; Solenoid valve faulty/blocked, PCB faulty. Cycle blocked with door closed. Drain pump always works (5 min., then it stops for 5 min. ecc.).
RESET EC3 Problems with Weight sensor (no signal or out of limits) Wiring faulty; Weight sensor faulty; PCB faulty. ---------------- START/RESET Ed1 Data communication error between WD board and PCB Wiring faulty between PCB and WD board; WD board faulty; PCB faulty. Cycle interrupted. OFF/ON Ed2 Drying heating element relay 1 faulty Wiring faulty between WD board and thermostats; thermostats faulty; WD board faulty, PCB faulty. Cycle blocked with door open. RESET Ed3 Drying heating element relay 2 faulty Wiring faulty between WD board and thermostats; thermostats faulty; WD board faulty, PCB faulty. Cycle blocked with door open.
RESET Ed4 Relay which commutates power between washing heating element and drying (in the WD board) Wiring faulty; WD board faulty; PCB faulty. Cycle blocked with door open. RESET Ed6 No communication between PCB and display board (INPUT) Wiring faulty between PCB and programme display board; PCB faulty. ---------------- OFF/ON